fix reliable_range for fio suites
diff --git a/wally/suits/itest.py b/wally/suits/itest.py
index a997b02..26fd252 100644
--- a/wally/suits/itest.py
+++ b/wally/suits/itest.py
@@ -2,11 +2,12 @@
import time
import logging
import os.path
-from typing import Any, List, Optional, Callable, Iterable, cast, Tuple
+from typing import Any, List, Optional, Callable, Iterable, cast
from concurrent.futures import ThreadPoolExecutor, wait
from cephlib.node import IRPCNode
+from cephlib.units import unit_conversion_coef_f
from ..utils import StopTestError, get_time_interval_printable_info
from ..result_classes import SuiteConfig, JobConfig, TimeSeries, IWallyStorage
@@ -173,7 +174,8 @@
self.name, job.summary,
max_start_time - min_start_time, self.max_time_diff)
- job.reliable_info_range = (int(max_start_time), int(min_stop_time))
+ one_s = int(unit_conversion_coef_f('s', results[0].time_units))
+ job.reliable_info_range = (int(max_start_time) + one_s, int(min_stop_time) - one_s)
self.storage.put_job(self.suite, job)
self.storage.sync()